Products List
6-36kV Fault Indicator
The normal reset time is 8 hours, but can meet customer's special requirement by setting prior to leaving factory.
Fault IndicatorApplication The fault indicator is always mounted on the branch line of each branch point to indicate the single phase earthing fault or short...
MV 630A,24kV Shielded Fore-Tee-Connector
1) EPDM material
2) Fully insulated and shielded
3) ISO9001:2000
4) Test Report
5) Exported to Korea, Vietnam, India etc
The Shielded Fore-Tee-connector is used for connection of polymeric cable to transformers, switchgears, motors and other...
Secondary Power Distribution System SF6 Gas Insulated Switchgear
1) All MV function units can be integrated flexibly
2) Small size
3)30 years free maintenance
4)ISO9001
5) Type test report
Data of Switch-disconnector Type Ring Main Unit ItemsUnitValueRated VoltagekV1224Rated CurrentA630630Rated FrequencyHz5050Rated Breaking...
Fault Indicator
1 .The reset time of the fault indicator can be set according to customer's requirements .
Fault IndicatorApplication The KFI series fault indicators are mounted on overhead line to indicate single phase earthing fault or short-circuit fault. In case of the single phase...
SF6 Gas Insulated Ring Main Unit
1 SF6 Ring Main Unit exported to Korea, Viet. and Pakistan
2 ISO 9001 Standard
3 OEM is accepted
4. Got Type Test report
ParametersNo.ItemValue1Rated Voltage24kV2Rated Current630A3Rated Frequency50Hz/60 Hz4Rated Breaking Current630A5Rated Short-circuit Making Current50 kA6Rated...
MV 630A,24kV Shielded Fore-Connector
1) EPDM material
2) Fully insulated and shielded
3) ISO9001:2000
4) Test Report
5) Exported to Korea, Vietnam, India etc
The Shielded Fore-Tee-connector is used for connection of polymeric cable to transformers, switchgears, motors and other...
6-35kV Fault Indicator
1.The reset time of the fault indicator can be set according to customer's requirements .
Fault IndicatorApplication The KFI series fault indicators are mounted on overhead line to indicate single phase earthing fault or short-circuit fault. In case of the single phase...
630A 24kV Separable Premold Deadbreak Front Tee Cable Connectors
Structure:Fully shielded, insulated and a total safe to touch
Material: EPDM Rubber
OEM is available
ISO9001:2008 Certificate
I. Application and Function: Seperable Premold Front Tee Cable Connector is designed to connect polymeric 12, 17.5 and 24 kV insulated cable to MV...
24kV 250A screened electrical elbow cable connector
1) EPDM Rubber
2) Standard: DIN47636
3) ISO9001:2008 Certificate
4) Type Test Report from authority
5) OEM is available
I. Application and Function: 250A screened separable elbow cable connector is designed to connect 12, 17.5 and 24 kV polymeric...
24kV, 600A Electrical Separable Premolded Deadbreak Rear Tee Cable Connectors
1) EOM is accepted
2) Exported to Korea, Vietnam, India and Brazil
3) AC withstand and partial discharge is done on each
Separable Rear Tee Connector is a fully shielded, molded rubber connector. It is designed to connect polymeric insulated cable to 600A Deadbreak Apparatus...